Fire Sprinkler Nozzle

Fire Sprinkler Nozzle
Product Introduction:
FRD005, 11.2 K-factor,Upright and Pendent Sprinklers,Standard Response, Standard Coverage. In the event of a fire, the fire water is evenly sprinkled through the fire sprinkler to control the fire in a certain area. Common types of fire sprinklers include: pendent, upright, ordinary and side wall
Description
Technical Parameters

The pendent fire sprinkler is the most widely used fire sprinkler. It is installed downwardly on the water supply branch pipe. The shape of the sprinkler is parabolic, spraying 80-100% of the total water to the ground. To protect rooms with suspended ceilings, fire sprinklers should be arranged under the suspended ceilings, and either pendent fire sprinklers or ceiling fire sprinklers should be used.


The upright sprinkler is installed upright on the water supply branch pipe. The sprinkler shape is parabolic, spraying 80-100% of the total water volume downwards, and part of it is sprayed to the ceiling. It is suitable for installation in places where there are many moving objects and easy to hit The warehouse can also be concealed on the roof of the room ceiling mezzanine to protect the ceiling of the ceiling with more combustible materials. (In places where the ceiling is not used, when the water distribution pipe is arranged under the beam, the upright type should be adopted. For the parts that are vulnerable to collision, the sprinkler with protective cover or the ceiling-type sprinkler should be used)


The 11.2 K-factor, FRD005 Sprinklers were subjected to full-scale, high-piled storage fire tests to qualify their use in lieu of 5.6 or 8.0 K-factor standard spray sprinklers for the protection of high-piled storage.


Physical Characteristics

Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . .Brass 

Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Brass 

Sealing Assembly Glass bulb 5mm. . . . . . . . . . . . . . . .Glass

Compression Screw . . . . . . . . . . . . . . . . . . . . . .Brass 

Deflector . . . . . . . . . . . . . . . . . . . . . . . . . .Brass

K=11.2 forede sprinkler

TABLE A


MODEL

FRD004

WORKING PRESSURE

175 psi (12,1 bar)

CONNECTION

3/4’’ BSP (NPT OPTIONAL)

K-FACTOR

11.2 GPM/psi½ (161,4 LPM/bar½)

TEMPERATURE RATING

 

155 ºF (68 ºC)

200 ºF (93 ºC)

286 ºF (141 ºC)

INSTALLATION

Upright

TABLE B


MODEL

FRD005

WORKING PRESSURE

175 psi (12,1 bar)

CONNECTION

3/4’’ BSP (NPT OPTIONAL)

K-FACTOR

11.2 GPM/psi½ (161,4 LPM/bar½)

TEMPERATURE RATING

 

155 ºF (68 ºC)

200 ºF (93 ºC)

286 ºF (141 ºC)

INSTALLATION

Pendent


 

Hot Tags: fire sprinkler nozzle, China, manufacturers, suppliers, wholesale, price, Fire Hydrant Landing Valve, Automatic Fire Fighting Water Monitor, Pendent Fire Sprinklers, Concealed Fire Sprinkler Head, Manual Fire Monitor, Sidewall Glass Bulb Fire Sprinklers