Manual Fire Monitor with SS304 Nozzle – Model WFS Series The Manual Fire Monitor with SS304 nozzle is an advanced firefighting device designed to deliver reliable and effective water and foam flow in emergency situations. Available in multiple models including WFS1.SF020, WFS1.SF030, WFS1.SF040, and WFS1.SS040, this equipment combines durability and high performance to enhance fire suppression capabilities.
Send Inquiry
Description
Technical Parameters

 
Products Description

 

Manual Fire Monitor With SS304 Nozzle

Key Features:
- Flow Rates: 1200 LPM, 1800 LPM, 2400 LPM, with customizable options ranging from 1200 to 2400 LPM to meet various firefighting demands.
- Working Pressure: Operates efficiently at 0.8 MPa, with a maximum working pressure of 1.6 MPa ensuring robust water delivery.
- Throw Range:
- Water: Ranges from ≥ 50 meters to ≥ 65 meters depending on the model, providing extensive coverage.
- Foam: Effective foam throw range from ≥ 45 meters to ≥ 60 meters for versatile fire-fighting applications.
- Angle Adjustability: Horizontal rotation from 0° to 330° and elevation from -45° to +75°, both customizable to suit different operational needs.
- Durable Construction: Equipped with a high-quality SS304 stainless steel nozzle that offers excellent corrosion resistance and long service life.
- Waterway and Connections: Features a 2.5-inch (DN65mm) waterway size, 2.5-inch NH outlet, and adaptable inlet options including 3"/4" BS4504 PN16 Flange, along with other customizable inlet configurations.

 

  • 2
    Manual Fire Monitor With SS304 Nozzle
  • 3
    Manual Fire Monitor With SS304 Nozzle
  • 2
    Manual Fire Monitor With SS304 Nozzle
  • 3
    Manual Fire Monitor With SS304 Nozzle
 
Products Detailed
ScreenShot2026-01-15135227218
Size
ScreenShot2026-01-15135239946
Angle
 
Technical Parameter 

How to Use the Manual Fire Monitor With SS304 Nozzle?

 

1. **Preparation:**
- Ensure the fire monitor is securely mounted or positioned.
- Check that all connections to the water or foam supply line are tight and leak-free.
- Confirm that the SS304 nozzle is clean and free of any obstructions.

2. **Connecting the Supply:**
- Connect the fire monitor to the water or foam supply system.
- Open the supply valve slowly to pressurize the system, reaching the working pressure of 0.8 MPa for optimal performance.

3. **Adjusting the Flow Rate:**
- Select the correct flow rate setting corresponding to your fire suppression needs: 1200 LPM, 1800 LPM, or 2400 LPM.
- For model WFS1.SS040, flow rate adjustments can be made within the 1200 to 2400 LPM range for flexible operation.

4. **Positioning the Monitor:**
- Rotate the monitor horizontally within the 0° to 330° range to cover the target area.
- Use the elevation control to adjust the angle between -45° and +75° based on the height and distance of the fire.

5. **Operating the Nozzle:**
- The SS304 nozzle ensures corrosion resistance and durability.
- Switch between water and foam streams if the system supports foam injection.
- Ensure that during foam use, the mixture ratio is correct for efficient fire suppression.

6. **Spraying:**
- Begin spraying by fully opening the nozzle.
- Observe the throw range, which can reach up to 65 meters for water and 60 meters for foam, providing excellent reach for firefighting operations.
- Continuously adjust the horizontal angle and elevation to target the fire effectively.

7. **After Use:**
- Close the nozzle and supply valve.
- Drain any remaining water or foam from the lines to prevent damage.
- Clean and inspect the nozzle and monitor to maintain readiness for the next use.

---

### Tips for Best Performance:

- Regularly inspect the SS304 nozzle and monitor components for signs of wear.
- Keep the working pressure steady at 0.8 MPa for consistent flow and maximum throw range.
- Customize the horizontal and elevation angles based on the specific scenario to maximize coverage.
- Use the foam option when fighting flammable liquid fires for superior effect.

Model

WFS1.SF020

WFS1.SF030

WFS1.SF040

WFS1.SS040

Flow Rate

1200LPM

1800LPM

2400LPM

1200-1800-2400LPM

Working Pressure

0.8 MPa

0.8 MPa

0.8 MPa

0.8 MPa

Max Working Pressure

1.6 MPa

1.6 MPa

1.6 MPa

1.6 MPa

Throw Range(water)

≥ 50 m

≥ 60 m

≥ 65 m

≥ 50-65 m

Throw Range(foam)

≥ 45 m

≥ 55 m

≥ 60 m

≥ 45-60 m

Horizontal Angle

0°~330° (angle customized)

Elevation Angle

-45°~+75° (angle customized)

Waterway Size

2.5'' (DN65mm)

Outlet

2.5'' NH

Inlet

3''/4'' BS4504 PN16 Flange, others customized

 

 

 
Application Area

 

 

 

QQ20240401145245

Rescue Services

22

Residential Buildings

 

33

Industrial Settings

44

Public Space

 
Frequently Asked Questions

Q: Can I choose the specifications of the fire monitor?

A: You can choose according to your needs.

Q: How to Use Fire Monitor?

A: 1. Connect the Monitor 2. Position the Monitor 3. Adjust the Flow 4. Aim the Nozzle 5. Monitor the Fire

Q: Can the Monitor Head of the Fire Monitor Be Replaced?

A: Yes, ensure that the fire equipment is fully operational only,the monitor head of a fire monitor can be replaced.

Q: What Are the Flange Standards for Fire Monitors?

A: The most commonly used flange standards for fire monitors include BS4504, ANSI150, GB, etc.

 

 
forede® Fire Monitor System Series
baiduimg.webp
图片尺寸 210x210
baiduimg.webp
Title
baiduimg.webp
Title
baiduimg.webp
Title
baiduimg.webp
Title
baiduimg.webp
图片尺寸 210x210
baiduimg.webp
Title
baiduimg.webp
Title
baiduimg.webp
Title
baiduimg.webp
Title

 

 

 
 
forede® Main Products
 
How to contact us?
How To Cooperate With Us?

Our address

Nan'an City, Quanzhou City Fujian PRC-china

Phone Number

2

 

 

Hot Tags: manual fire monitor with ss304 nozzle, China, manufacturers, suppliers, wholesale, price, Cast Iron Fire Hydrant, Water Cannon, Fire Sprinklers For Storage, Open Spray Nozzle, Foam Monitor System Design, Truck Mounted Water Cannon

 

 

Send Inquiry
Quanzhou Forede Firefighting Equipment Co.,Ltd
contact us