Products Description

Overview
Warehouse sprinkler heads are specially designed for rack storage & high-piled warehouse occupancies. Main types include ESFR and CMSA sprinklers with high K-factors and large water droplets to penetrate fire plumes. ESFR achieves early fire suppression, while CMSA provides fire control for high-challenge storage risks.
Storage Type: Palletized, rack, bin box, shelf, or solid-pile.
Storage Height & Ceiling Height: Determines pressure, flow rate, and sprinkler type.
Water Supply: Must meet discharge density and duration requirements.
System Type: Wet pipe, dry pipe, preaction, or deluge depending on environment.
Features
Product Name: Warehouse sprinkler heads
Material: Brass
K Factor: K25
Installation: Pedent
Response: CMSA
Products Specification
Warehouse sprinkler heads with different size and standard for option:
|
Model Number |
Connection | K factor | Tempurature |
Max. Height |
Installation Spacing |
|
CMSAX 363 -74°C Y |
1" (DN25) BSP |
K25@US (363@Metric) |
74°C |
7.5/ 9/12m |
2.4~3.7m |
FAQ
Q: What types of sprinkler heads are commonly used in warehouses?
The most common types include:
Upright sprinklers: Installed above piping, used in open or obstructed areas.
Pendent sprinklers: Installed below piping, suitable for smooth ceilings.
ESFR (Early Suppression Fast Response) sprinklers: Designed for high-challenge storage fires.
CMSA (Control Mode Specific Application) sprinklers: Used for specific storage configurations.
In-rack sprinklers: Mounted within racks to protect high-piled storage.
Q: What is the difference between ESFR and CMSA sprinklers?
ESFR sprinklers are designed to suppress fires rapidly, reducing the need for in-rack sprinklers.
CMSA sprinklers control the fire instead of suppressing it completely and may require in-rack protection depending on the storage height and type.
Q: How are sprinkler heads selected for a warehouse?
Selection depends on several factors:
Type of stored materials (combustibility)
Storage height and configuration
Ceiling height and building structure
Water supply pressure and flow
Applicable fire codes (e.g., NFPA 13)
Q: What is the temperature rating of warehouse sprinkler heads?
Warehouse sprinklers typically range from 155°F (68°C) to 286°F (141°C) depending on ambient temperature and application.
Recommend Products
Contact Us
Hot Tags: warehouse sprinkler heads, China, manufacturers, suppliers, wholesale, price, Sprinkler Accessories, Breeching Inlet, Glass Bulb ESFR Fire Sprinklers, Fire Truck Water Cannon, K17 Fire Sprinkler Heads, Dry Sprinkler Heads