Fm200 Fire Suppression System Price

Fm200 Fire Suppression System Price
Product Introduction:
HFC-227ea is one of the most widely used gas fire extinguishing systems at present. Many protection areas such as computer rooms, power distribution rooms, archives, containers, etc. are equipped with HFC-227ea fire extinguishing systems.
Description
Technical Parameters

1) Chemical inhibition: HFC-227ea fire extinguishing agent can inert the active free radicals in the flame and block the chain reaction during combustion;


2) Cooling: When the HFC-227ea fire extinguishing agent is sprayed out of the nozzle, the liquid fire extinguishing agent rapidly transforms into a gaseous state and needs to absorb a lot of heat, which reduces the temperature around the flame in the protection zone;


3) Asphyxiation: The spray of fire extinguishing agent in the protected area reduces the concentration of oxygen and reduces the moderateness of combustion.1

SYSTEM DATA

Model

QMQ4.2/90N-JM

QMQ4.2/120N-JM

QMQ4.2/150N-JM

Cylinder Capacity (L)

90

120

150

Max. Working Pressure (MPa)

5.3

Storage Pressure (MPa)

4.2

Working Temperature Range

0~50°C (System room); -10°C (Min Temp. in protection area)

Charging Rate (Kg/L)

≤0.95

Air actuating Pressure (MPa)

6

Operating Voltage (V)

AC220

Back-Up Power (V)

DC24

Discharging Time (S)

≤10

System Startup Method

Automatic / manual / emergency operation


Agent Cylinder

 

The fire extinguishing agent cylinder filled by JUNMO with HFC-227ea, and super-pressurised with dry nitrogen to 25 bar @ 21℃ (360 psi @ 70°F) and 42 bar @ 21℃ (600 psi @ 70°F).

JUNMO Agent Cylinders sharing the same manifold shall be equal in size and fill density. Cylinders are finished in red and are available in various sizes.

 

_20210729114012


Volume


Fill Capacity 

(kg)

Maximum

Fill Capacity 

(kg)

Minimum

Outlet Size

Height

Diameter

Empty Weight

40L

19.2

44.8

33/49

830

324

42.0

50L

24.0

56.0

33/49

950

324

43.6

60L

28.8

67.2

33/49

1100

324

49.9

70L

33.6

78.4

49

1250

324

56.2

80L

38.4

89.6

49

1400

324

62.6

90L

43.2

100.8

49

1200

406

68.4

100L

48.0

112.0

49

1310

406

72.4

120L

57.6

134.4

49

1245

406

96.2

150L

72.0

168.0

49

1495

406

113.1

180L

86.4

201.6

49

1745

462

130.2


 

Hot Tags: fm200 fire suppression system price, China, manufacturers, suppliers, wholesale, price, Cabinet FM 200 Fire Suppression System, Cabinet FM 200 Fire Protection System, Portable Ground Monitor, Cabinet FM 200 Fire Protection


-Low concentration of HFC

-227ea required means less visual obscurity and minimal risk to personnel.

-Small quantity of agent discharged minimises over pressurisation of the protection area.

-Max Safety for personnel due to low toxicity.

-High effective with 10 second discharge time when used with automatic detection.

-Prevent re-ignition as long as concentration levels are maintained.

-Two kinds of working pressure system are available,(25 bar / 360 psi and 42 bar / 600 psi).


Send Inquiry
Quanzhou Forede Firefighting Equipment Co.,Ltd