Wet Alarm Check Valve Assembly

Wet Alarm Check Valve Assembly
Product Introduction:
Overview Model WAV-1 Alarm Check Valve is a wet pipe sprinkler system water supply check valve that makes possible the installation of sprinkler systems in buildings not subject to freezing temperatures. It is designed so that water pressure in the piping system will hold back water pressure at...
Send Inquiry
Description
Technical Parameters
Products Description

 

1

Alarm Check Valve

 

Model WAV-1 Alarm Check Valve is a wet pipe sprinkler system water supply check valve that makes possible the installation of sprinkler systems in buildings not subject to freezing temperatures. It is designed so that water pressure in the piping system will hold back water pressure at the valve until a significant flow of water occurs such as a sprinkler is activated.

 

 

 

 

 

Products Parameters

 

Size
4" (DN100)
6" (DN150)
Inlet Connection Style
Flange
Flange
Outlet Connection Style
Flange Flange
Shipping Weight
55lbs∕25kg
75lbs∕34kg
Max. Working Pressure
175 psig∕1.2 MPa (12 bar)
Factory Hydro Test
100% @ 350 psig∕2.4 MPa (24 bar)
Standard Finish
Red Painted
Flange Specification
Flange: Class 150 ANSI B16.1
Required Accessories
Standard Trim
Optional Accessories
Retard Chamber, Water Motor Alarm, Alarm Pressure Switch
Installation Manner
Vertically
Listings and Approvals
FM APPROVAL

 

Instructions

 

The trim sets for the Model WAV-1 Alarm Valve are arranged for rapid, easy and compact attachment, and serves as connection points to Alarm and other devices. The trim also serves as means for testing the operation of the alarm devices without causing the system to operate.

 

1. Constant Pressure Closed Drain

This trim set is used where water supply pressure does not vary, such as tank supplies. An automatic draining is provided to drain the mechanical sprinkler alarm line. This drain connection should be piped separately from the 2" (50mm) main drain.

 

2. Variable Pressure With Open Retard Chamber Drain

Retard Chamber is required. This trim set is used where water supply pressures vary, such as encountered with city water supplies. An open drip cup should be provided to drain the retard chamber and the mechanical sprinkler alarm line. This drain connection should be piped separately from the 2" main drain.

 

 

Hot Tags: wet alarm check valve assembly, China, manufacturers, suppliers, wholesale, price