Stack Tips Water Cannon

Stack Tips Water Cannon
Product Introduction:
The Stack Tips Water Cannon is built with quality and durability in mind. It incorporates a 2.5-inch (DN65mm) waterway size and a 2.5-inch NH outlet, ensuring reliable water flow and easy integration with standard firefighting equipment. The inlet flange options include 3-inch or 4-inch BS4504 PN16, with other customized fittings available to suit various installation demands.
Send Inquiry
Description
Technical Parameters

 
Products Description

 

Stack Tips Water Cannon

 

Stack Tips Water Cannon Model TFS1.AZ4 is a state-of-the-art firefighting solution designed to deliver powerful and reliable performance in critical situations. With a versatile flow rate ranging from 1200 to 3000 liters per minute, this water cannon ensures efficient and effective fire control, adapting seamlessly to various firefighting needs.

Operating at a standard working pressure of 0.8 MPa and capable of withstanding a maximum working pressure of 1.6 MPa, the TFS1.AZ4 offers robust pressure management that guarantees consistent water output. Its impressive throw range of at least 70 meters enables firefighters to reach distant flames quickly, enhancing safety and operational reach.

Engineered for flexibility, the water cannon features a wide horizontal rotation angle adjustable from 0° to 330°, with customizable options to meet specific requirements. Additionally, the elevation angle ranges from -45° to +75°, providing comprehensive coverage for both high and low targets. This adaptability empowers firefighting teams to tackle fires in diverse environments effectively.

 

  • 4
    Stack Tips Water Cannon
  • 2
    Stack Tips Water Cannon
  • 5
    Stack Tips Water Cannon
 
Products Detailed

 

1
Angle
2
Angle

 

 
Products Feature

 

 

Flow Rate

The flow rate of the manual foam fire monitor tiller control is an essential feature that enables firefighters to control and direct the flow of water and foam. These flow rates are essential for fighting fires of different magnitudes and intensities.

Working Pressure

Working pressure is crucial for the efficiency and effectiveness of firefighting operations. 8 Bar ensures that the water and foam are delivered at adequate pressure to extinguish the fire.

Foam Jetting Range

The foam jetting range is the distance over which the foam can be projected onto the fire.These ranges enable firefighters to tackle fires from a safe distance and prevent injuries.

Water Jetting Range

The water jetting range is the distance over which the water can be projected onto the fire. These ranges allow firefighters to combat fires from a safe distance and prevent further damage.

Foam Expansion

The foam expansion is the number of times the foam increases in volume when mixed with water. 

Outlet

All three models of manual foam fire monitor tiller controls have a 2.5" NH outlet, which is required for proper connection of the device to water sources and hoses.

 

 

 
Technical Parameter 

How to Maintain the Stack Tips Water Cannon?

 

The Stack Tips Water Cannon, Model TFS1.AZ4, is a robust and high-performance firefighting tool designed to deliver powerful water streams with flow rates ranging from 1200 to 3000 liters per minute. With a working pressure of 0.8 MPa and a maximum working pressure up to 1.6 MPa, this water cannon ensures a throw range of 70 meters or more, making it an indispensable asset for any fire protection system. To maintain its excellent performance and reliability, consistent maintenance is essential. Here are practical and positive tips to keep your water cannon operating perfectly.

#### 1. Regular Cleaning
Keeping the waterway clear of debris and sediment ensures a steady flow and prevents blockages. After each use, flush the cannon with clean water to remove any residues. Periodically inspect the inlet flange (3''/4'' BS4504 PN16 flange or customized fittings) and outlet (2.5'' NH) for any buildup and clean as necessary.

#### 2. Inspect Moving Parts
The water cannon's horizontal angle (0° to 330°) and elevation angle (-45° to +75°) capabilities rely on smooth movements. Regularly check and lubricate the swivel joints and elevation mechanisms to maintain fluid motion and avoid stiffness. Use appropriate lubricants recommended by the manufacturer to guarantee longevity.

#### 3. Check Seals and Connections
Ensuring tight and secure connections is vital for maintaining working pressure and preventing leaks. Inspect seals, gaskets, and flange bolts regularly, replacing any worn or damaged parts promptly. This helps uphold the maximum working pressure of 1.6 MPa, ensuring safety and performance.

#### 4. Monitor Flow Rate and Pressure
Periodically verify that the water cannon delivers the rated flow rate between 1200LPM and 3000LPM and operates within the specified pressure range. This monitoring confirms that the system is performing optimally and can detect early signs of irregularities.

#### 5. Customize and Upgrade
The Stack Tips Water Cannon offers customizable options for horizontal and elevation angles to suit specific operational needs. Stay in touch with suppliers to explore any new enhancements or accessories that can increase efficiency and adaptability.

#### 6. Store Properly
When not in use, store the water cannon in a clean, dry environment. Protect it from harsh weather conditions to prevent corrosion and wear, preserving its excellent condition for future use.
 

 

 

Model

TFS1.AZ4

Flow Rate

1200LPM-3000LPM

Working Pressure

0.8 MPa

Max Working Pressure

1.6 MPa

Throw Range(water)

≥ 70 m

Horizontal Angle

0°~330° (angle customized)

Elevation Angle

-45°~+75° (angle customized)

Waterway Size

2.5'' (DN65mm)

Outlet

2.5'' NH

Inlet

3''/4'' BS4504 PN16 Flange, others customized

 

Application Area

 

 

 

QQ20240401145245

Rescue Services

22

Residential Buildings

 

33

Industrial Settings

44

Public Space

 
Frequently Asked Questions

Q: Can I choose the specifications of the fire monitor?

A: You can choose according to your needs.

Q: How to Use Fire Monitor?

A: 1. Connect the Monitor 2. Position the Monitor 3. Adjust the Flow 4. Aim the Nozzle 5. Monitor the Fire

Q: Can the Monitor Head of the Fire Monitor Be Replaced?

A: Yes, ensure that the fire equipment is fully operational only,the monitor head of a fire monitor can be replaced.

Q: What Are the Flange Standards for Fire Monitors?

A: The most commonly used flange standards for fire monitors include BS4504, ANSI150, GB, etc.
 
forede® Fire Monitor System Series
baiduimg.webp
图片尺寸 210x210
baiduimg.webp
Title
baiduimg.webp
Title
baiduimg.webp
Title
baiduimg.webp
Title
baiduimg.webp
图片尺寸 210x210
baiduimg.webp
Title
baiduimg.webp
Title
baiduimg.webp
Title
baiduimg.webp
Title

 

 

 
 
forede® Main Products
 
How to contact us?
How To Cooperate With Us?

Our address

Nan'an City, Quanzhou City Fujian PRC-china

Phone Number

2

 

 

Hot Tags: Stack Tips Water Cannon, China, manufacturers, suppliers, wholesale, price, Portable Fire Water Monitor, Fire Sprinklers For Storage, Fixed Fire Water Monitor, Sprinkler Head, Fire Hydrant Water Monitor, Fire Fighting Water Monitors

 

 

Send Inquiry
Quanzhou Forede Firefighting Equipment Co.,Ltd
contact us