Dry Riser Breeching Inlet
forede ® Dry Riser Breeching Inlet is an essential component of fire protection systems in high-rise buildings and structures. It is designed to provide a connection point for firefighters to access water supply from outside the building and deliver it to higher floors in case of a fire emergency.
forede ® Dry Riser Breeching Inlet is located at the ground level or in the basement of the building. It is connected to a water supply source such as a municipal water main, reservoir, or pump. The inlet is also equipped with a valve that can be closed or opened to regulate the water flow.
In the event of a fire, firefighters can connect their hoses to the forede ® Dry Riser Breeching Inlet and activate the valve to draw water from the source. The water is then pumped up to the floors where the fire is located, using a network of pipes and outlets commonly known as dry risers.
The advantages of having a forede ® dry riser breeching inlet in a building cannot be overemphasized. It provides a reliable source of water supply, especially in high-rise buildings where traditional firefighting methods may not be effective. It also saves time and reduces the risk of injury to firefighters who would otherwise have to carry heavy hoses up the stairs to reach the fire.
Products Specification
Features
Body Material: Ductile Iron
Inlet Adaptor: Cooper Alloy
W. pressure: 24 bar
Chains: Stainless Steel
Cap: ABS Plastic
Gate Valve: Cooper Alloy
forede ® Dry riser breeching inlet is an essential component of any building's fire safety system. It facilitates quick and efficient access to water supply during emergencies, enabling firefighters to extinguish fires quickly and prevent damage to property and lives
| Model | 4BI-150/65 | |
| Body Material | Ductile Iron | |
| Max Working Pressure | 2.4 Mpa | |
| Outlet | 4*2.5 BS336 Male Inst | |
| Inlet Connection | 6" BS4504 Flange Connection | |
FAQ
Frequently Asked Questions
What is a dry riser breeching inlet for a dry riser?
-
Breeching inlet (Inlet breeching) is normally located on the ground floor of building to enable the fire and rescue service to connect hoses to supply water into dry riser, so that water can be pumped up to higher floors.
What is the function of dry riser breeching inlet?
-
Dry riser breeching inlets are installed outside the building or any easily accessible area in the building for fire brigade personnel to access the inlet. This inlet is used by the fire brigade personnel to access water.
What is the difference between a fire hydrant and a dry riser breeching inlet?
-
Fire hydrants provide an emergency water supply to firefighters in urban or suburban areas to extinguish fires, whereas breeching inlets are essentially access points through which firefighters can pump water into a building using hoses.
Where is the dry riser breeching inlet located?
-
The dry riser breeching inlets shall be located on the external wall above ground level nearest to the vertical run of the riser stack. The maximum horizontal run of the water pipe between the breeching inlets and the same riser stack shall not exceed 12 m.
What is the difference between a 2-way and 4-way breeching inlet?
-
Normally there are two types of inlet breeching available, one is 2-way another is 4-way. The 2-way version has 2 x 2½" Instantaneous male non-return valve inlets and a 4″ outlet while the 4-way inlet breeching has 4 x 2½" Instantaneous male non-return valve inlets and a 6 outlet along with 1″ drain valve
forede Fire Hydrant System Series
forede Main Product
Our Main Products
Contact Us
How To Cooperate With Us?
Our address
No.278-1, Meiting Village, Meilin Sub-District,
Nan'An City, Quanzhou City Fujian Province China
Phone Number
+86 18750638978(Wendy)
sales4@forede.com

Hot Tags: dry riser breeching inlet, China, manufacturers, suppliers, wholesale, price, Flanged Foot Valve, Different Types Of Fire Nozzles, Pendent ESFR Fire Sprinklers, Fire Sprinkler Guard, Positioning Fire Water Monitor, Rubber Expansion Joints