productcate-1600-900
 
 

Landing Valves Brief Introduction

forede® landing valve, also known as hydrant valve or fire hydrant landing valve, is an important part of indoor fire hydrant system.It is suitable for installation on wet risers system and dry riser system in commercial & residencial buildings for fire fighting purposes, permanently charged with water from a pressurized supply,usually installed in fire hydrant boxes and used in conjunction with fire hoses, water guns and other fire fighting equipments. They can be wall-mounted or attached to standpipes, and the water flow can be adjusted to different levels depending on the type of fire and the building's water supply.They are Globe valves that are installed on hydrants, a branch and hose is connected to a coupling on it. 

 

One of the main advantages of a fire landing valve is its reliability. This device is designed to withstand high pressure and extreme conditions, ensuring that it functions properly when needed the most. With a simple twist of the valve handle, fire personnel can quickly gain access to water and extinguish a fire before it grows out of control.Another benefit of a fire landing valve is its easy installation and maintenance. They are reliable, easy to install, maintain, and customize to fit specific building needs. With the right installation and maintenance, fire landing valves can provide effective protection for buildings and the people who use them. 

 
 

 

 

 

 

Types of Fire Hydrant Landing Valve

 

 

What we have ?

forede® offers types of fire hydrant landing valve to meet different kinds of customer's request .Over last 15 years,forede has developed typs of wet riser and dry riser landing valve to meet with commercial & residencial buillding with different height for fire fighting purpose.Below is forede's types of fire hydrant landing valve.

Oblique Type Landing Valves 

Straight Through Landing Valves

Pressure Self Regulating Landing Valve

Bib-Nose Type Landing Valves

Right Angle Landing Valves

Dry Riser Fire Hydrant Landing Valves

 

 

 Oblique Type Landing Valve-wet Riser Application

forede® Oblique hydrant landing valves are designed to be easily accessible and convenient for firefighters. They are installed in a downward-facing position, at an angle of 45 degrees from the vertical, to allow water to flow smoothly and efficiently. This type of valve is ideal for high-rise buildings as it ensures that water can be delivered to the upper floors without losing pressure or volume.This type of hydrant valves have DN65 (2 1/2”) male threaded or flange inlets; outlet hose connection complies with BS336 standard and is equipped with blanking cap and a chain.All components of oblique landing valve are corrosion resistant or coated with a thermally applied fusion-bonded epoxy.

Hydrant Valve Type Inlet Connection Outlet Connection Working Pressure Material
Oblique Type Flange Type BS336 Instantaneous Coupling 20 Bar (290PSI) Copper Alloy
Oblique Type Male Thread Type BS336 Instantaneous Coupling 20 Bar (290PSI) Copper Alloy

 Straight Through (Horizontal) Landing Valve-wet Riser Application

forede® horizontal hydrant landing valve in a wet riser system is one of an important component playing a vital role in ensuring the safety of a commercial residencial building. This kind of hydrant landing valve is designed to allow firefighters easy access to water in case of a fire emergency. Installing such a valve in a wet riser system is necessary as it not only helps in extinguishing a fire quickly but also minimizes the damage caused by the fire.This type of hydrant valves have DN65 (2 1/2”) male threaded or flange inlets; outlet hose connection complies with BS336 standard and is equipped with blanking cap and a chain.All components of straight through (horizontal) landing valve are corrosion resistant or coated with a thermally applied fusion-bonded epoxy.

Hydrant Valve Type Inlet Connection Outlet Connection Working Pressure Material
Straight Through Flange Type BS336 Instantaneous Coupling 20 Bar (290PSI) Copper Alloy
Straight Through Male Thread Type BS336 Instantaneous Coupling 20 Bar (290PSI) Copper Alloy

 Bib-Nose Landing Valve-Wet Riser Application

forede® Bib Nosed Globe Hydrant Valves are outlets commonly used on stand pipes, wet pillar hydrant systems or dry riser systems.It is manufactured in accordance with BS 5041-1 and BS 5154 standards. This type of hydrant valves have DN65 (2 1/2”) male threaded or flange inlets; outlet hose connection complies with BS336 standard and is equipped with blanking cap and a chain.All components of Bib-nosed landing valve are corrosion resistant or coated with a thermally applied fusion-bonded epoxy.

Hydrant Valve Type Inlet Connection Outlet Connection Working Pressure Material
Bib Nosed Flange Type BS336 Instantaneous Coupling 20 Bar (290PSI) Copper Alloy
Bib Nosed Male Thread Type BS336 Instantaneous Coupling 20 Bar (290PSI) Copper Alloy

 Right Angle Landing Valve-Wet Riser Application

forede® Right Angled Globe Hydrant Valves are outlets commonly used on stand pipes, wet pillar hydrant systems or dry riser systems. forede Right Angle Hydrant Valve is manufactured in accordance with BS 5041-1 and BS 5154 standards. This type of hydrant valves have DN65 (2 1/2”) male threaded or flange inlets; outlet hose connection complies with BS336 standard and is equipped with blanking cap and a chain.All components of right angle landing valve are corrosion resistant or coated with a thermally applied fusion-bonded epoxy.

Hydrant Valve Type Inlet Connection Outlet Connection Working Pressure Material
Right Angle Flange Type BS336 Instantaneous Coupling 20 Bar (290PSI) Copper Alloy
Right Angle Male Thread Type BS336 Instantaneous Coupling 20 Bar (290PSI) Copper Alloy

Pressure Regulating Landing Valve (PRV)

forede® pressure self regulating landing valves are suitable for installation on wet risers in commercial ,residencial ,industrial buildings for fire protection purposes. Pressure regulating landing valve allows the user to set the valve outlet pressure as desired according to the conditions of the fire protection system in which the valves are installed. The constant set outlet pressure of the valve protects the fireman from inconsistent hose pressure in a fire protection system.It is manufactured in accordance with BS 5041-1 and BS 5154 standards. This type of hydrant valves have DN65 (2 1/2”) male threaded or flange inlets; outlet hose connection complies with BS336 standard and is equipped with blanking cap and a chain.All components of pressure regulating landing valve are corrosion resistant or coated with a thermally applied fusion-bonded epoxy.

Hydrant Valve Type Inlet Connection Outlet Connection Working Pressure Material
Pressure Regulating Valve Flange Type BS336 Instantaneous Coupling 20 Bar (290PSI) Copper Alloy
Pressure Regulating Valve Male Thread Type BS336 Instantaneous Coupling 20 Bar (290PSI) Copper Alloy

Dry Riser Landing Gate Valve

forede® dry riser landing valves are outlets from the riser main. The valves are situated on each floor of a high rise building and are usually housed in an outlet cabinet. Padlocks and straps are available on request.It is manufactured in accordance with BS 5041-1 and BS 5154 standards. This type of hydrant valves have DN65 (2 1/2”) male threaded,female thread or flange inlets; outlet hose connection complies with BS336 standard and is equipped with blanking cap and a chain.All components of dry riser landing valve are corrosion resistant or coated with a thermally applied fusion-bonded epoxy.

Hydrant Valve Type Inlet Connection Outlet Connection Working Pressure Material
Gate Valve Flange Type BS336 Instantaneous Coupling 20 Bar (290PSI) Copper Alloy
Gate Valve Male Thread Type BS336 Instantaneous Coupling 20 Bar (290PSI) Copper Alloy
Gate Valve Female Thread Type BS336 Instantaneous Coupling 20 Bar (290PSI) Copper Alloy
Advantages of forede® Landing valves

Strong Strength

forede® landing valves are suitable for indoor fixed fire-fighting facilities such as factories, warehouses, high-rise buildings, public buildings.

High Manufacturered Standard

All types of forede® fire hydrant landing valves are manufactured,tested,marked,packed in accordance with BS 5041-1,BS336 and BS 5154 standards.

Corrosion Resistant

forede® landing valves mainly made of copper alloy, some of the models applied the gunmetal to adapt different situations.All components of fire hydrant landing valve are corrosion resistant or coated with a thermally applied fusion-bonded epoxy.

Complete Range And Application

We have designed more than 6 types of forede® landing valves according to BS 5041-1,BS336 and BS 5154 standards.To meet the request of dry riser(Dry risers are a legal requirement in buildings more than 18m tall. They’re typically only used in buildings between 18m and 50m) and wet riser (Wet risers are a legal requirement in buildings over 50m tall )system in commercial & residencial buillding.

 

 

 

  • Thread Type Landing Valve
    The forede® LVT.OB-65 thread type landing valve is indoor pipe network water supply to the fire site, with valve interface, for factories, warehouses, high-rise buildings, public buildings and...
    read more
  • Landing Valve in Fire Fighting
    The forede® LVF.OB-65 brass landing valve is typically installed at the end of a fire hose and is used to regulate the amount of water that is released. It is an important tool for firefighters as...
    read more
  • Fire Hydrant Valve 2.5
    forede ® 2.5 inch Fire Hydrant Valve is an essential tool for firefighters to quickly access water during emergencies. With its durable construction and reliable performance, this valve ensures...
    read more
  • 2-1/2 Oblique Landing Valve
    forede ® 2-1/2 Oblique Landing Valve is an essential component in fire fighting systems, providing a reliable water supply for firefighters to extinguish flames quickly and efficiently. Its...
    read more
  • Hydrant Valve Oblique
    forede ® Oblique Type Hydrant Valve is an essential component in fire emergency response systems. It is designed to control the flow of water in a fire hydrant system. It plays a critical role in...
    read more
  • Landing Valve 65mm
    forede ® Landing Valve 65mm is a critical component in fire protection systems, specifically designed for use in high-rise buildings, commercial complexes, and industrial facilities.
    read more
  • 2.5 Inch Landing Valve
    forede® 2.5 Inch Landing Valve is a specialized fire-fighting equipment designed for connecting fire hoses and nozzles, featuring a 2.5-inch diameter outlet. It is typically made of brass and cast...
    read more
  • Single Headed Landing Valve
    forede® Single Headed Landing Valve is a valve with a single inlet/outlet point, designed for precise fluid control in hydrant systems. It offers simplified installation, maintenance, and...
    read more
  • Gate Hydrant Valve
    forede® Gate Hydrant Valve is a robust fluid control device featuring a perpendicular gate disc for reliable sealing. It is designed for hydrant systems, offering durable performance and precise...
    read more
  • 2.5 Hydrant Gate Valve
    forede® 2.5 Hydrant Gate Valve is a robust fluid control device with a 2.5-inch diameter, featuring a perpendicular gate disc for full open/close functionality. Made of durable materials, it...
    read more
  • Landing Gate Valve
    forede® Landing Gate Valve is a specialized valve used in multi-story buildings to control water flow to hydrants on specific floors. It features a gate that moves perpendicular to the flow...
    read more
  • Pn16 Landing Valve
    forede® PN16 Landing Valve is a specialized valve rated for a maximum working pressure of 1.6 MPa (16 bar). It controls fluid flow at specific points in a building, such as landings or floors,...
    read more
First 1234567 Last
 

 

 

Landing valves Applications
QQ20241106133439
01

‌Wet Riser

Landing valve classify the wet riser, an essential part of any building’s fire safety system. Its purpose is to provide a reliable source of water to firefighters in the event of a fire. A wet riser is a vertical pipe that is permanently charged with water and runs throughout a building, with outlets at each floor level.

When a fire breaks out, firefighters can connect their hose to the wet riser outlet, allowing them to access the water supply immediately. This saves crucial time in extinguishing the fire and can ultimately help save lives. A wet riser is particularly important in high-rise buildings, where firefighters would otherwise have to transport heavy equipment and hoses up multiple flights of stairs.

The effectiveness of a wet riser depends on its proper installation and maintenance. Regular inspections and testing ensure that the system is functional and ready for use in an emergency situation. Building owners and managers have a responsibility to ensure that their wet riser system is up to code and in good working order.

02

Dry Riser

Landing valve classify the dry riser, is designed to help firefighters easily access water on all floors and compartments during fire fighting emergencies. Made up of a system of water inlets, pipes, and outlets spread out through a building across all levels, these systems are normally situated along the building's fire fighting shaft.

 

In the event of a fire, firefighters need a reliable source of water to help them extinguish the flames as soon as possible. With a dry riser in place, they can quickly connect their hoses to the system and deliver water to any part of the building that needs it. Another important purpose of dry risers is to help prevent fires from spreading. By providing a reliable source of water throughout the building, dry risers can help contain fires and prevent them from spreading to other floors or areas of the building. This is especially important in large or multi-story buildings, where fires can quickly become difficult to control.

 

Dry risers can also help to reduce damage caused by fires. By quickly delivering water to the source of the fire, firefighters can extinguish flames before they have a chance to cause extensive damage. This can help to limit the costs of repairs and ensure that the building is back in use as soon as possible.

QQ20241106111736
QQ20241105152649
03

High-Rise buildings

The landing valves, especially dry risers outlet should be on each floor of a high-rise building. This enables firefighters to get to a specific floor without having to drag a hose from the fire truck up the stairs. In residential buildings, dry risers need to be within a fire resistant shaft.

 

Landing valves can be divided into two types, one is a dry riser and the other is a wet riser. A dry riser refers to a dry pipe installed indoors. When a fire occurs, compressed air and water are passed through the pipe to spray water through the fire hydrant. Wet riser has water flowing in the pipe. Once a fire occurs, water can be sprayed directly and quickly to transfer the fire source and extinguish the fire.

 

In high-rise buildings, the role of landing valves are particularly critical. Once a fire occurs in a building, it takes a long time for the fire department to arrive at the fire scene, and the density of people in high-rise buildings, making escape difficult and risky. Therefore, before the fire department arrives, landing valves can work with firefighting equipment to save the lives and property of people and property.

04

Marine

The landing valves are indispensable part of the ship's fire protection system, and it plays a very important role in fires. They are water source that can provide emergency water for firefighters when a fire occurs. When a fire breaks out, the landing valves can provide direct water supply, and firefighters can access firefighting equipments in time to quickly control the fire and put it out.

 

In addition, the landing valves can also be used as a water supply source for other equipment on the ship. For example, the toilets and bathing facilities on the ship require water sources, and the landing valves can provide a clean and hygienic water source.

 

The landing valves can also be used as an emergency treatment measure for water leaks or leaks. If a ship leaks or leaks during navigation, it can provide a timely emergency water source to avoid the expansion of the danger.

QQ20241105155411
 

 

 

We're well-known as one of the leading landing valve manufacturers and suppliers in China for our quality products and good service. Please feel free to wholesale landing valve at competitive price from our factory. Contact us for more details.

Angle Landing Valve, Oblique Thread Landing Valve, Ground Monitor
Send Inquiry
Quanzhou Forede Firefighting Equipment Co.,Ltd
contact us