Dry Riser Inlet Vertical Cabinet

Dry Riser Inlet Vertical Cabinet
Product Introduction:
The forede® Brand FRD-DRIV dry riser inlet vertical cabinet is an essential firefighting equipment that provides a source of water supply for firefighters in tall buildings or structures. The cabinet is usually located in a designated area within a building and contains various components, including valves, pipes, and hoses. The cabinet is equipped with a dry riser system, which is a series of vertical pipes that run through the building and are connected to each floor. In the event of a fire, firefighters can connect their hoses to the dry riser system, allowing water to flow to the fire.
Send Inquiry
Description
Technical Parameters
Products Description
3

Overview

 

The forede® Brand FRD-DRIV dry riser inlet vertical cabinet – house the inlet breaching valve, these valves, connected via pipe work, allow the initial connection to the dry riser system. They feed the dry riser outlets sited within outlet cabinets on each floor of the building.

 

The dry riser inlet vertical cabinet installed in a building can greatly improve the safety and effectiveness of firefighting efforts. It ensures that firefighters have immediate access to a reliable water supply, helping to minimize the damage caused by the fire.

 

Features

 

 Cabinet and Door: 16swg Zintec Steel or Stainless, Satin Polished.

 Glass: Yes.

 Lock: Slam Lock with Key.

 Hinge: Stainless Steel.

 Hinge Type: Piano.

 Aperture: 605(High) x 405(Wide) x 305(Deep) mm.

 

Products Parameters

 

forede® dry riser inlet vertical cabinet with different size and standard for option: 

Part Number Material Installation Dimensions (H×W×D)
Thickness
FRD-DRIV-M Mild Steel Semi-recessed 605 x 405x 305, Customized 1.0/1.2/1.5/2.0mm
FRD-DRIV-S
Stainless Steel
Semi-recessed 605 x 405x 305, Customized 1.0/1.2/1.5/2.0mm

 

FAQ

 

Q: What is a dry riser inlet vertical cabinet?

Dry riser inlet vertical cabinet is designed to help firefighters easily access water on all floors and compartments during fire fighting emergencies. Made up of a system of water inlets, pipes, and outlets spread out through a building across all levels, these systems are normally situated along the building's fire fighting shaft.

 

Q: What are the requirements for a dry riser inlet vertical cabinet?

An external inlet needs to be located on the exterior wall on the ground floor. It should sit within an enclosure with a sign indicating that it is a dry riser inlet vertical cabinet. The enclosure should hold a collecting head with no less than two instantaneous male hose connections and a drain down valve.

 

Q: Where does the dry riser inlet vertical cabinet used?

The dry riser Inlet vertical cabinet is an important piece of fire safety equipment used in large buildings where firefighters may need to access water quickly during a fire emergency. These cabinets are typically located on every floor of a high-rise building, and they contain the necessary piping and hoses to supply water to a fire. The cabinet itself is usually mounted on a wall or floor, and it is easily visible and accessible to emergency responders.

 

Q: What's the difference between dry riser Inlet vertical cabinet and wet riser inlet cabinet?

The dry riser inlet vertical cabinet and a wet riser inlet cabinet are two different systems that are used for fire protection. The main difference between the two is that a dry riser inlet vertical cabinet is used in buildings where there is no water supply, while a wet riser inlet cabinet is used in buildings that have access to a water supply.

Dry riser inlet vertical cabinet is a system that is used in high-rise buildings and other structures where there is no water supply available. This system consists of a cabinet that houses a dry riser valve and other firefighting equipment. The dry riser valve is connected to a network of pipes that run throughout the building. In the event of a fire, firefighters can connect hoses to the dry riser valve and use it to pump water up to the upper floors of the building.

On the other hand, a wet riser inlet cabinet is a system that is used in buildings with a water supply. This system consists of a cabinet that houses a wet riser valve and other firefighting equipment. The wet riser valve is connected to a network of pipes that run throughout the building and are connected to a water supply. In the event of a fire, firefighters can connect hoses to the wet riser valve and use it to pump water throughout the building.

 

Related Products

 

product-450-450
Fire Hydrant & Standpipe
f5763ad4ab536cf6a4d94e632ec4d33a
Landing Valve
product-450-450
Fire Hose Rack & Assembly
product-300-300
Fire Hose Reel & Assembly
product-450-450
Breeching Inlet & FDC
cabinet
Fire Cabinet
product-300-300
Jet/Spray Nozzle
fire hose
Fire Hose
product-300-300
Delivery Hose Coupling &Adaptor & Cap
product-300-300
Air Release Valves
Recommend Products
product-450-450
Handline Fire Nozzle
product-450-450
Fire Monitor
Foam Extinguishing System
Foam Extinguishing System
Fire Sprinkler System
Fire Sprinkler System
Fire Protection Valve
Fire Protection Valve
Fire Hydrant Systems
Fire Hydrant System
UL FM Equipment
UL / FM Equipment
Water truck parts
Water Truck Parts
Fire Truck Acessories
Fire Truck Accessories
Fire Suppression System
Fire Suppression System 
Contact Us

Our address

Nan'an City, Quanzhou City Fujian PRC-China

Phone Number

+86 13215065797

E-mail

sales5@forede.com

QQ20241028115245

 

Hot Tags: dry riser inlet vertical cabinet, China, manufacturers, suppliers, wholesale, price, Angle Landing Valve Fire Fighting, Grooved Wet Type Alarm Valve, Pistol Grip Selectable Fire Nozzle, Alcohol Resistant Aqueous Film Forming, Signal Gate Valve, Mf 140 Mobile Foam Unit

 

 

Send Inquiry
Quanzhou Forede Firefighting Equipment Co.,Ltd
contact us