Products Description

Overview
The forede® FRD-DPH150 dry hydrant is a vital tool often used by firefighters to access water sources in areas where traditional hydrants do not exist. It is essentially an underground pipe with a non-permanent connection that can be hooked up to a fire engine to provide an immediate source of water. The dry hydrant is intended for use in all climates including those where freezing occurs. A single main valve is in the base for hydrant fully open or closed.
Features
Product Name: Dry hydrant
Body: Cast Iron
Finishing: Painting
Control Valve: Cooper Alloy W/ Cap&Chain
Working Pressure: 16 Bar
Products Parameters
forede® dry hydrant with different size and standard for option:
Model
|
Working Pressure |
Flange
|
Hose Outlet | Pumper outlet |
FRD-DPH150
|
16 Bar |
6" Table E BS10
|
2 X 2.5"NH
|
4" NH |
FRD-DPH150 | 16 Bar | 6" Table E BS10 | 2 X 2.5"NH | 5" NH |
FAQ
Q: What is the material of dry hydrant?
The body of the FRD-DPH150 dry hydrant is made of cast Iron construction.
Q: What is dry hydrant system?
A dry hydrant is a non-pressurized pipe system permanently installed in a water source such as lakes, streams or ponds that permits the withdrawal of water by drafting from a fire truck to provide a reliable water source for fire suppression close to the incident.
Q: What is the thickness of dry hydrant for outdoor?
Normmally, FRD-DPH150 dry hydrant for outdoor thickness is 1.0-1.2mm, meet the Chinese natioanl standard.
Q: Can a Dry hydrant be used in freezing temperatures?
Dry hydrants must comply with the relevant fire safety regulations and standards, such as NFPA 24 and local building codes. They should also be inspected and tested regularly to ensure their proper operation.
Q: Are there any regulations or standards that apply to dry hydrants?
1. Daily inspection: Check the status of dry hydrant for outdoor, including appearance, signs, connection parts, etc., to ensure their normal operation. If any abnormal situation is found, it should be reported and handled in time.
2. Cleaning: Clean the pillar fire hydrant for outdoor regularly to remove dirt and rust on the surface to ensure their neat appearance.
3. Tightening: Check the tightness of the connection parts of the fire hydrant regularly. If there is any looseness, tighten it in time to prevent water leakage.
4. Lubrication: Lubricate the rotating parts of the fire hydrant for regularly, such as rotating nozzles, movable connection parts, etc., to ensure their flexible rotation and movement.
Related Products
Recommend Products
Contact Us
Hot Tags: dry hydrant, China, manufacturers, suppliers, wholesale, price, Automatic Scanning Positioning Fire Monitor, Foam Bladder Tank Fire Fighting, Flange Type Swing Check Valve, Flange End Silent Check Valve, Branch Foam Inductor, Horizontal Foam Bladder Tank