Products Description

Overview
The forede® FRD-DPH150 dry type pillar hydrant gets its name from the fact that water is drained from the barrel when not in use. It is intended for use in all climates including those where freezing occurs. A single main valve is in the base for hydrant fully open or closed.
Features
Product Name: Dry type pillar hydrant
Body: Cast Iron
Finishing: Painting
Control Valve: Cooper Alloy W/ Cap&Chain
Working Pressure: 16 Bar
Products Parameters
forede® dry type pillar hydrant with different size and standard for option:
|
Model
|
Working Pressure |
Flange
|
Hose Outlet | Pumper outlet |
|
FRD-DPH150
|
16 Bar |
6" Table E BS10
|
2 X 2.5"NH
|
4" NH |
| FRD-DPH150 | 16 Bar | 6" Table E BS10 | 2 X 2.5"NH | 5" NH |
FAQ
Q: What is the material of dry type pillar hydrant?
The body of the FRD-DPH150 dry type pillar hydrant is made of cast Iron construction.
Q: What is dry type pillar hydrant system?
A dry type pillar hydrant is a non-pressurized pipe system permanently installed in a water source such as lakes, streams or ponds that permits the withdrawal of water by drafting from a fire truck to provide a reliable water source for fire suppression close to the incident.
Q: What is the thickness of pillar fire hydrant for outdoor?
Normmally, FRD-WPH150 pillar fire hydrant for outdoor thickness is 1.0-1.2mm, meet the Chinese natioanl standard.
Q: Can a Dry Type Pillar Hydrant be used in freezing temperatures?
Dry Type Pillar Hydrants must comply with the relevant fire safety regulations and standards, such as NFPA 24 and local building codes. They should also be inspected and tested regularly to ensure their proper operation.
Q: Are there any regulations or standards that apply to Dry Type Pillar Hydrants?
1. Daily inspection: Check the status of pillar fire hydrant for outdoor, including appearance, signs, connection parts, etc., to ensure their normal operation. If any abnormal situation is found, it should be reported and handled in time.
2. Cleaning: Clean the pillar fire hydrant for outdoor regularly to remove dirt and rust on the surface to ensure their neat appearance.
3. Tightening: Check the tightness of the connection parts of the fire hydrant regularly. If there is any looseness, tighten it in time to prevent water leakage.
4. Lubrication: Lubricate the rotating parts of the fire hydrant for regularly, such as rotating nozzles, movable connection parts, etc., to ensure their flexible rotation and movement.