Products Description
Blabber Mouth Foam Monitors
The 2400LPM Fixed Fire Monitor series includes multiple models tailored to meet diverse operational needs:
- **Model TFS1.AF020**: Flow rate of 1200LPM
- **Model TFS1.AF030**: Flow rate of 1800LPM
- **Model TFS1.AF040**: Flow rate of 2400LPM
- **Model TFS1.AS040**: Adjustable flow rates between 1200-1800-2400LPM
All models operate at a working pressure of 0.8 MPa with a maximum working pressure of 1.6 MPa, ensuring consistent and robust performance under demanding conditions. The impressive throw range enhances safety and firefighting reach:
- Water throw range up to 65 meters
- Foam throw range extending to 60 meters
Products Detailed


Technical Parameter
How to Use the Blabber Mouth Foam Monitors?
#### 1. **Preparation and Safety Checks**
- **Inspect the Monitor:** Before operation, thoroughly inspect the monitor to ensure all components are intact and securely fastened. Look for any signs of damage or wear.
- **Check Water or Foam Supply:** Confirm that the water or foam supply is sufficient and the hoses are properly connected.
- **Verify Working Pressure:** Ensure the water pressure is maintained at 0.8 MPa for optimal performance, with the capability to handle up to 1.6 MPa if needed.
#### 2. **Positioning and Setup**
- **Confirm Fixed Installation:** This monitor is designed for fixed mounting, so ensure it is securely installed on a stable platform or fire truck mount.
- **Set the Direction:** Adjust the monitor's horizontal and vertical angles to aim towards the target fire area. With a throw range exceeding 65 meters (water), precise aiming is critical for effective reach.
- **Select Flow Type:** Choose between water or foam output depending on the fire type. Foam application is especially effective for flammable liquid fires and provides a throw range of about 60 meters.
#### 3. **Operation**
- **Activate Water or Foam Flow:** Open the supply valve slowly to gradually build up pressure and flow, preventing sudden surges.
- **Control and Adjust Aim:** Use the monitor's control handles (manual or hydraulic) to adjust the stream direction smoothly, ensuring coverage of the fire zone.
- **Maintain Steady Flow:** The 2400 LPM flow rate delivers a powerful stream, capable of suppressing large fires efficiently. Keep the flow consistent for best results.
#### 4. **Post-Operation**
- **Shut Down Properly:** Close the supply valve to stop the water or foam flow.
- **Drain Residual Water:** Clear any residual water from the monitor to prevent corrosion or freezing in cold conditions.
- **Perform Routine Maintenance:** Regularly clean and lubricate moving parts to keep the monitor in peak condition for future use.
|
Model |
TFS1.AF020 |
TFS1.AF030 |
TFS1.AF040 |
TFS1.AS040 |
|
Flow Rate |
1200LPM |
1800LPM |
2400LPM |
1200-1800-2400LPM |
|
Working Pressure |
0.8 MPa |
0.8 MPa |
0.8 MPa |
0.8 MPa |
|
Max Working Pressure |
1.6 MPa |
1.6 MPa |
1.6 MPa |
1.6 MPa |
|
Throw Range(water) |
≥ 50 m |
≥ 60 m |
≥ 65 m |
≥ 50-65 m |
|
Throw Range(foam) |
≥ 45 m |
≥ 55 m |
≥ 60 m |
≥ 45-60 m |
|
Horizontal Angle |
0°~330° (angle customized) |
|||
|
Elevation Angle |
-45°~+75° (angle customized) |
|||
|
Waterway Size |
2.5'' (DN65mm) |
|||
|
Outlet |
2.5'' NH |
|||
|
Inlet |
3''/4'' BS4504 PN16 Flange, others customized |
|||
Application Area

Rescue Services

Residential Buildings

Industrial Settings

Public Space
Frequently Asked Questions
Q: Can I choose the specifications of the fire monitor?
Q: How to Use Fire Monitor?
Q: Can the Monitor Head of the Fire Monitor Be Replaced?
Q: What Are the Flange Standards for Fire Monitors?
forede® Fire Monitor System Series










forede® Main Products
How to contact us?
Our address
Nan'an City, Quanzhou City Fujian PRC-china
Phone Number
Hot Tags: 2400lpm fixed fire monitor, China, manufacturers, suppliers, wholesale, price, Elevated Fire Monitor, Fixed Foam Monitor, Dry Riser Landing Valve, Multi Purpose Fire Nozzles, Open Spray Nozzle, Fixed Fire Monitor