Fire Sprinklers For Storage

Fire Sprinklers For Storage
Product Introduction:
forede Fire Sprinklers For Storage are installed in places where the slope of the building roof or ceiling does not exceed 170mm/m. The sprinkler splash plate must be installed parallel to the ceiling or ceiling. The nozzle spacing should not be less than 2.4m and should not be greater than 3.7m. When the height of the protected object is greater than 7.5m or the clearance height of the protected space is greater than 9m, the nozzle spacing should not be greater than 3m.
Send Inquiry
Description
Technical Parameters

The Induction of Fire Sprinklers For Storage

forede Fire Sprinklers For Storage is a main component of the automatic sprinkler system has special advantages for protecting high-stack warehouses.It can be used in cylindrical packaging paper product warehouses. And protection of rubber tire warehouses. The fusible connection component is connected by two equal-length connectors through a thin welding layer.When the operating temperature is reached, the welding layer melts, the connecting parts are separated, and the sprinkler starts to spray fire.


The Specification of Fire Sprinklers For Storage

K FACTORK17@US(242@Metric)
Thread SizeDN20(3/4")
Connecting ThreadBSP(NPT Optional)
Main MaterialBrass
Sensitive Element Fusible Alloy
Seal Material NBR(Teflon Optiona)
Surface Finishing
Natural Brass
Temperature74°C,100°C


The FAQ of Fire Sprinklers For Storage


Q1:What is the production time of the Fire Sprinklers For Storage?
A sample of Fire Sprinklers For Storage will be produced within 15 days


Q2: Can we make field trips and visit your factory?
Yes, We are pleased you come to visit our factory.Welcome!

Q3: What is the minimum order quantity of Fire Sprinklers For Storage?
For conventional Fire Sprinklers For Storage , Low MOQ.

 

Hot Tags: fire sprinklers for storage, China, manufacturers, suppliers, wholesale, price, K17 Fire Sprinkler Heads, Breeching Inlet, Glass Bulb ESFR Fire Sprinklers, K363 Fire Sprinkler For Storage, DN20 K202 Fire Sprinkler Heads, Automatic Fire Fighting Monitor

1)Use the fusible alloys as sensitive components has stable performance, precise operating temperature, and fast response speed.

2)By installing ESFR sprinkler heads in the overhead system, the layered sprinkler heads on each shelf can be eliminated, thus simplifying the system and saving investment costs.