Sprinkler Alarm Check Valve Assembly

Sprinkler Alarm Check Valve Assembly
Product Introduction:
forede Fire Sprinkler System Wet Valves are core components of wet pipe sprinkler systems, with a durable metal body and clapper mechanism. The system’s piping is pre-filled with water, enabling instant water discharge when a sprinkler head activates due to fire, while triggering integrated on-site and remote alarms.​ Key advantages: instant fire suppression, high reliability, low maintenance, integrated alarms, and wide compatibility with sprinkler configurations.​ Ideal for environments above 4°C, including commercial, institutional, residential, and light industrial buildings. Proper use involves pre-operation commissioning, routine maintenance, and post-fire reset.​ These valves ensure the wet sprinkler system’s reliable performance, delivering rapid, effective fire protection and enhancing safety across diverse scenarios.
Send Inquiry
Description
Technical Parameters
Products Description

Sprinkler Alarm Check Valve assembly

 

 

forede Fire Sprinkler System Wet Valves are core pressure-control components for wet pipe sprinkler systems, where piping is permanently filled with pressurized water. Featuring a corrosion-resistant ductile iron/stainless steel body and spring-assisted clapper mechanism, the valve maintains standby pressure under normal conditions. When a fire melts a sprinkler head's fusible link, the sudden pressure drop opens the clapper, enabling instant water discharge and activating on-site (hydraulic gong) and remote (pressure switch) alarms via the integrated alarm port.​ Key advantages include instant water release (zero lag for rapid fire suppression), high reliability (simplified hydraulic design with fewer moving parts), low maintenance costs (easy upkeep and modular component replacement), integrated alarm functionality (enhancing emergency coordination), and wide compatibility (adapting to diverse sprinkler heads and piping configurations). These traits make them suitable for environments above 4°C, including commercial/retail buildings, institutional facilities (hospitals, schools), high-rise residential buildings, and light industrial/warehouse facilities with controlled temperatures.​

-1
 
 
Features:
- Body Material: Ductile Iron,QT450;
- Seal Disc Material: 304 Stainless Steel With NBR;
- Ball Valve &Strainer &Check Valve: Brass Standard;
- Retard Chamber: Carbon Steel Standard;
- Water Motor Gong: Carbon Steel Standard;
- Piping Accessories: Galvanized Pipe Standard;
 
Alarm

Valve Type

 
1.6Mpa

Working Pressure

 
3''-10''

size

 
1 Year

Warrnty

Specification
 
 
Technical Parameters

Model Number

Size

Flange Standard

Installation

Working Pressure

ZSFZ 80

DN80(3'')

BS4504

Vertical

1.6 Mpa

ZSFZ 100

DN100(4'')

BS4504

Vertical 

1.6 Mpa

ZSFZ 125

DN125(5'')

BS4504

Vertical

1.6 Mpa

ZSFZ 150

DN150(6'')

BS4504

Vertical 

1.6 Mpa

ZSFZ 200

DN200(8'')

BS4504

Vertical 

1.6 Mpa

ZSFZ 250

DN250(10'')

BS4504

Vertical 

1.6 Mpa

Frequently Asked Question
Frequently Asked Questions
 
 

Q. What is a Wet Alarm Valve?

 

-

A: Wet Alarm Valve is the critical control unit in a wet pipe sprinkler system. It maintains water pressure in supply pipes while monitoring flow. When a sprinkler activates, it:

Releases water into distribution pipes.

Triggers alarms via mechanical & electrical signals.
Composition: Valve clapper, retard chamber, alarm port, and test drains.

Q. Advantages of Wet Alarm Valves

 

-

A: Instant Response: 3-5 second water release after sprinkler activation.

Ultra-Reliable: No electronics – operates on water pressure alone.

Low Maintenance: Annual inspection vs. quarterly checks for dry systems.

False Alarm Prevention: Retard chamber filters pressure surges.

Leak Detection: Test valves monitor seal integrity continuously.

Q. Why Choose Wet Alarm Valve Sprinkler System?

 

-

A: Life-Saving Speed: 50% faster water delivery than dry/pre-action systems.

Cost-Effective: 30% lower installation/maintenance costs.

Simplicity: No air compressors, priming delays, or complex controls.

Fail-Safe Operation: Functions during power outages.

Q. How the Valve Operates?

 

-

A:  Standby: Water pressure holds clapper closed.

Activation: Sprinkler opens → pressure drop lifts clapper.

Flow: Water enters sprinkler pipes.

Alarm Sequence:

Water fills retard chamber (5-60 sec delay).

Activates water motor gong (mechanical bell).

Triggers pressure switch (electronic alarm).

Reset: Close main valve → drain → inspect → repressurize.

Q. Where we should use check alarm valve?

-

A:The check alarm valve is an essential component of any fire protection system. It is designed to provide reliable and efficient protection in critical applications, such as high-rise buildings, power plants, and industrial facilities. In short, we should use check alarm valves wherever there is a risk of fire and a need for an effective fire suppression system.

One of the main benefits of check alarm valves is their ability to control or stop the flow of water through the system at the right time. This is particularly important in a fire situation, where the last thing you want is for the water to continue flowing even when it's no longer needed. Check alarm valves help to ensure that water is delivered where and when it's needed, which can significantly reduce the damage caused by fire.

Another advantage of check alarm valves is their ability to provide early warning of system failure. If there is a problem with the fire suppression system, the check alarm valve will sound an alarm that alerts you to the issue. This means that you can address the problem before it gets out of hand, reducing the chances of a fire breaking out and causing damage to your property.

Check alarm valves are also useful in situations where there is a risk of freezing or overheating. They are designed to release water at a consistent rate, even in extreme temperatures, which helps to protect the system and prevent damage to the building.

In conclusion, check alarm valves are a critical component of any fire protection system. They help to ensure that water is delivered where and when it's needed, provide early warning of system failure, and protect against freezing or overheating. By using check alarm valves in the right applications, we can help to keep our buildings and facilities safe and prevent the spread of fire.

Recommend Product
 
FIRE SPRINKLER SYSTEM
 
Standard Spray Sprinklers
Standard Spray Sprinkelrs
Storage Sprinklers
Storage Sprinklers
Extended Coverage Sprinklers
Extended Coverage Sprinklers
Dry Sprinklers
Dry Sprinklers
concealed sprinkler
Concealed Sprinklers
Spray Nozzles
Spray Nozzles
Sprinkler Accessories2
Sprinkler Accessories
Main Product
Our Main Product

Handline Fire Nozzle
Handline Fire Nozzle
product-450-450
Fire Monitor
Foam Extinguishing System
Foam Extinguishing System
Fire Sprinkler System
Fire Sprinkler System
Fire Protection Valve
Fire Protection Valve
Fire Hydrant Systems
Fire Hydrant System
UL FM Equipment
UL FM Equipment
Water truck parts
Water Truck Parts
Fire Truck Acessories1
Fire Truck Accessories
Fire Suppression System
Fire Suppression System
Contact Information
How To Cooperate With Us?

Dear Customer,
Before ordering, please contact with our sales team to discuss order information, such as Model Number, Flow Rate, Material, Control Ways, Package,Etc.
If you have any other requirements or wanna know more info about our products, welcome to contact as well. Our Sales team and Technical Department are willing to support you.

Our address

Nan'an City, Quanzhou City Fujian PRC-China

Phone Number

shutterstock2875111731

 

Hot Tags: sprinkler alarm check valve assembly, China, manufacturers, suppliers, wholesale, price, Grooved Wet Type Alarm Valve, Groove Type Alarm Valve, Foot Type Valve With Strainer, Grooved Wet Type Alarm Check Valve, Groove Type Alarm Check Valve, Fire Signal Butterfly Valve

Send Inquiry
Quanzhou Forede Firefighting Equipment Co.,Ltd