Fixed manual fire monitors, also known as water cannons, are an essential component of every fire truck. They are used to deliver large volumes of water or fire-retardant solution to extinguish fires or control hazardous situations. The PS10/30-50W-T model of fixed manual fire monitor is one of the most advanced and effective tools for firefighting.
Send Inquiry
Description
Technical Parameters

 

 
Products Description

 

Fixed Manual Fire Monitors---Water Cannon On Fire Truck

 

This water cannon has a flow rate of 1800-2400-3000 LPM (Liters per Minute) and is equipped with an adjustable nozzle. It operates at a working pressure of 10 bar and has a maximum reach of 70 meters at 3000 LPM. The maximum fog angle of this water cannon is 120°.

 

This PS10/30-50W-T model has the ability to rotate 360°, and it can be adjusted vertically from -45° to +70°. The waterway size of this monitor is 2.5" (65mm) and the monitor outlet is 2.5" (65mm) NH male thread. The monitor inlet is flange 4" BS4504 as standard, but other sizes and standards are also available.

 

The material used to manufacture this water cannon is of high quality. Both the monitor and nozzle are made of aluminum alloy, which is not only lightweight but also durable. The tiller, that is the handle used to control the water cannon, is made of SS304 stainless steel, which is sturdy and resistant to wear and tear.

  • 1
    Fixed Manual Fire Monitors-Water Cannon On Fire Truck
  • 4
    Fixed Manual Fire Monitors-Water Cannon On Fire Truck
  • 5
    Fixed Manual Fire Monitors-Water Cannon On Fire Truck
  • 2
    Fixed Manual Fire Monitors-Water Cannon On Fire Truck
 
Products Detailed
product-1148-595
Angle
product-1148-595
Part Name
 
factroy photos
 
2
Fixed Manual Fire Monitors---Water Cannon On Fire Truck
4
Fixed Manual Fire Monitors---Water Cannon On Fire Truck

 

 

 

 
Technical Parameter 

What Is Fixed Manual Fire Monitors-Water Cannon On Fire Truck?

 

Fixed manual fire monitors, also known as water cannons, are an essential component of a fire truck. These devices are specifically designed to help firefighters tackle large fires quickly and efficiently. Water cannons are typically mounted onto the roof or front bumper of a fire truck and are operated using a manual control system.

 

One of the biggest advantages of fixed manual fire monitors is their ability to deliver a high volume of water to the fire. This makes them ideal for combating large fires where a huge amount of water is needed to extinguish the flames. They can also be used to create a water curtain to protect firefighters working on the front lines.

 

In addition to being effective at tackling large fires, fixed manual fire monitors are also incredibly versatile. They can be angled and adjusted to cover specific areas and can be used to reach otherwise inaccessible parts of a building or structure.

 

Another advantage of fixed manual fire monitors is their ease of use. They require minimal training and can be operated by a single firefighter, making them an essential tool in emergency situations.

Model Number

PS10/30-50W-T

Flow Rate

1800-2400-3000 LPM Adjustable Nozzle

Working Pressure

10 Bar

Max. Reach @ 10 bar

70 meters @ 3000 LPM

Max. Fog Angle

120°

Max Range Of Monitor

-45° to +70° Vertically, 360° Rotation

Waterway Size

2.5"(65mm)

Monitor Outlet

2.5"(65mm) NH male thread

Monitor Inlet

Flange 4" BS4504 is standard ( other sizes & standards are available )

Material

Monitor & Nozzle - aluminium alloy

Tiller - SS304 Stainless steel

 
Application Area

 

 

 

QQ20240401145245

Rescue Services

22

Residential Buildings

 

33

Industrial Settings

44

Public Space

 
Frequently Asked Questions

Q: Can I choose the specifications of the fire monitor?

A: You can choose according to your needs.

Q: How to Use Fire Monitor?

A: 1. Connect the Monitor 2. Position the Monitor 3. Adjust the Flow 4. Aim the Nozzle 5. Monitor the Fire

Q: Can the Monitor Head of the Fire Monitor Be Replaced?

A: Yes, ensure that the fire equipment is fully operational only,the monitor head of a fire monitor can be replaced.

Q: What Are the Flange Standards for Fire Monitors?

A: The most commonly used flange standards for fire monitors include BS4504, ANSI150, GB, etc.

 

 
Products Workshop
 

 

-

FIRE

           NOZZLES

-

FIRE

MONITORS

DSC10720

FOAM 

CONCENTRATE

product-377-307

GENERAL

VALVE

 

 
Order steps

 

1

Determine parameters

Confirm the production details of the order with sales staff.

2

Place order

Pay a deposit or full payment.

3

Production

After payment, we arrange production

4

 Shipment

Confirm the shipping address and shipping fee, then you can ship the goods.

 
 
forede® Main Products
 
How to contact us?
How To Cooperate With Us?

Our address

Nan'an City, Quanzhou City Fujian PRC-china

Phone Number

2

 

 

Hot Tags: water cannon on fire truck, China, manufacturers, suppliers, wholesale, price, Remote Water Foam Monitor, Grooved Wet Type Alarm Valve, AR AFFF Fire Fighting Foam, Foam Sprinkler Foam System, Flanged Flexible Disc Check Valve, Low Expansion Foam Sprinkler Head

 

Features:

Aluminium alloy construction;

Flow Rate: 1800-2400-3000 LPM (Adjustable);

Jetting Pattern: Straight stream,Fog;

Flange standard: BS4504,ANSI150,GB,etc.

.